首页> 美国政府科技报告 >Study of the Emission Performance of High-Power Klystrons: SLAC XK-5
【24h】

Study of the Emission Performance of High-Power Klystrons: SLAC XK-5

机译:高功率速调管的发射性能研究:sLaC XK-5

获取原文

摘要

There are hundreds of high power klystrons operated in the Linac gallery and about fifty to sixty tubes fail every year. The lifetime ranges from a few thousand up to seventy thousand hours except those which fail during an early period. The overall percentage of failures due to emission problems is approximately 25%. It is also noted that a 10% increase in mean lifetime of klystrons will reduce the overall cost per hour as much as a 10% increase in efficiency. Therefore, it is useful to find some method to predict the expected life of an individual tube. The final goal has not been attained yet, but some useful information was obtained. It is thought that this information might be helpful for those people who will study this subject further. (ERA citation 06:033673)