Cryogenic Voltage Withstand and Heat Transfer Tests for the General Electric Large Coil Turn Heaters

机译:通用电大型线圈转向加热器的低温耐压和传热试验

获取原文

摘要

The cryogenic hipot tests indicate that undamaged heaters will perform acceptably in the coil. However, the 1050 V dc hi-pot test does not appear adequate to diagnose all flaws. It was decided that during coil production the heaters will be tested with at least 1400 V dc and 400 V ac. Further tests at lower voltages will be performed after the heated conductor section is wound into the coil, with a final test at the layer of 900 V dc or 1.5 times the operating voltage. On the basis of the heat transfer tests, the power supply for the heaters will be specified to provide voltage pulses of up to 1000 V at 60 A for a maximum of 1 sec. (ERA citation 09:021534)