首页> 美国政府科技报告 >Neutron Slowing-down Time in Finite Water Systems
【24h】

Neutron Slowing-down Time in Finite Water Systems

机译:有限水系统中子减速时间

获取原文

摘要

The influence of the size of a moderator system on the neutron slowing-down time has been investigated. The experimental part of the study was performed on six cubes of water with side lengths from 8 to 30 cm. Neutrons generated in pulses of about 1 ns width were slowed down from 14 MeV to 1.457 eV. The detection method used was based on registration of gamma radiation from the main capture resonance of indium. The most probable slowing-down times were found to be 778 +- 23 ns and 898 +- 25 ns for the smallest and for the largest cubes, respectively. The corresponding mean slowing-down times were 1205 +- 42 ns and 1311 +- 42 ns. In a separate measurement series the space dependence of the slowing-down time close to the source was studied. These experiments were supplemented by a theoretical calculation which gave an indication of the space dependence of the slowingdown time in finite systems. The experimental results were compared to the slowing-down times obtained from various theoretical approaches and from Monte Carlo calculations. All the methods show a decrease of the slowing-down time with decreasing size of the moderator. This effect was least pronounced in the experimental results, which can be explained by the fact the measurements are spatially dependent. The agreement between the Monte Carlo results and those obtained using the diffusion approximation or the age-diff. (Atomindex citation 13:655376)