首页> 美国政府科技报告 >COBRA-WC Pretest Predictions and Post-Test Analysis of the FOTA Temperature Distribution During FFTF Natural-Circulation Transients
【24h】

COBRA-WC Pretest Predictions and Post-Test Analysis of the FOTA Temperature Distribution During FFTF Natural-Circulation Transients

机译:FFTF自然循环瞬态期间FOTa温度分布的COBRa-WC预测试预测和后测试分析

获取原文

摘要

The natural circulation tests of the Fast Flux Test Facility (FFTF) demonstrated a safe and stable transition from forced convection to natural convection and showed that natural convection may adequately remove decay heat from the reactor core. The COBRA-WC computer code was developed by the Pacific Northwest laboratory (PNL) to account for buoyancy-induced coolant flow redistribution and interassembly heat transfer, effects that become important in mitigating temperature gradients and reducing reactor core temperatures when coolant flow rate in the core is low. This report presents work sponsored by the US Department of Energy (DOE) with the objective of checking the validity of COBRA-WC during the first 220 seconds (sec) of the FFTF natural-circulation (plant-startup) tests using recorded data from two instrumented Fuel Open Test Assemblies (FOTAs). Comparison of COBRA-WC predictions of the FOTA data is a part of the final confirmation of the COBRA-WC methodology for core natural-convection analysis. (ERA citation 08:020727)