首页> 美国政府科技报告 >Evaluation of Neutron Flux Density and Power Density with SPN-Detectors and Micro Calorimeters. A Comparison
【24h】

Evaluation of Neutron Flux Density and Power Density with SPN-Detectors and Micro Calorimeters. A Comparison

机译:用spN探测器和微量热仪评估中子通量密度和功率密度。一个对比

获取原文

摘要

During investigations with a special equipped fuel assembly in the Rheinsberg nuclear power station the neutron flux and the power density were evaluated from measurements with SPN-detectors and micro calorimeters. The reliability of both detector types, their measurement accuracy under different physical conditions and the usefulness of the developed calculation models are discussed in detail. The thermal flux and the power density evaluated with SPND's agree well with theoretical results. The values obtained through micro calorimeter measurements are systematic lower by about 18%. This deviation is probably a result of differences in the used calculation models. (Atomindex citation 14:772544)