首页> 美国政府科技报告 >Common Cause Analysis of the TREAT Upgrade Reactor Protection System
【24h】

Common Cause Analysis of the TREAT Upgrade Reactor Protection System

机译:TREaT升级反应堆保护系统的常见原因分析

获取原文

摘要

A triply redundant reactor scram system (RSS) has been designed for the upgraded TREAT facility. The independent failures reliability goal for the RSS is <10 exp -9 failures per demand. An independent failures analysis indicated that this goal would be met. In addition, however, recognizing that in heavily redundant systems common-cause failures dominate, a common cause analysis of the TREAT upgrade RSS was done. The objective was to identify those common-cause initiators which could affect the functioning of the RSS, and to subsequently modify the design of the RSS so that the effect was minimized. A number of common-cause initiators were identified which were capable of defeating the triple redundancy feature of the reactor scram system. By means of a systematic analysis of the effect these initiators could have on the system, it was possible to identify seven necessary design and procedural modifications that would greatly reduce the probability of the reactor being run while the RSS was in a faulted condition. (ERA citation 10:009901)