首页> 美国政府科技报告 >Piezoelectric response of precisely poled PVDF to shock compression greater than 10 GPa
【24h】

Piezoelectric response of precisely poled PVDF to shock compression greater than 10 GPa

机译:精确极化pVDF的压电响应对冲击压力大于10 Gpa

获取原文

摘要

Prior work has shown that the piezoelectric response of shock-compressed PVDF film prepared with attention to mechanical and electrical processing exhibits precise, well-defined, reproducible behavior to 10 GPa. Higher pressure response continues to pressures approaching 50 GPa, and appears to provide a basis for a very high pressure stress-rate gauge. Previous work shows that differences in response were sometimes observed. The present report describes studies in progress undertaken to increase the precision of the polarization of the PVDF and to develop optimum sensors and shock gauge package designs. Results obtained on such careful prepared PVDF shock gauges show that differences in electrical charge response less than few percent are observed between 10 and 25 GPa.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号