首页> 美国政府科技报告 >Thermal performance of clean horizontal radiant barriers under winter conditions: Laboratory measurements and mathematical modeling.
【24h】

Thermal performance of clean horizontal radiant barriers under winter conditions: Laboratory measurements and mathematical modeling.

机译:冬季条件下清洁水平辐射屏障的热性能:实验室测量和数学建模。

获取原文

摘要

Several field experiments have been performed on attic radiant barriers under winter conditions; however, most of them have been confined to the fairly mild climates of Florida, Oklahoma, and Tennessee. Only one field experiment in a very cold climate (Canada) has been performed. In addition, no previous laboratory experiments under winter conditions have been performed on an attic both with and without a radiant barrier. This paper presents the results of laboratory measurements of the thermal performance of clean horizontal radiant barriers in a simulated residential attic module under nighttime or low solar gain daytime winter conditions. Comparing tests under the same conditions with and without a radiant barrier shows that the addition of a clean horizontal radiant barrier to insulation at the R-22 to R-25 level decreases the ceiling heat flow by 6 to 8%. The experimental results were found to be in very good agreement with predictions made with a mathematical model for the thermal performance of attics.