Studies suggest that the risk of severe accidents during low power operation and/or shutdown conditions could be a significant fraction of the risk at full power operation. The Nuclear Regulatory Commission has begun two risk studies to evaluate the progression of severe accidents during these conditions: one for the Surry plant, a pressurized water reactor (PWR), and the other for the Grand Gulf plant, a boiling water reactor (BWR). This paper summarizes the approach taken for the Level 2/3 analysis at Surry for one plant operating state (POS) during shutdown. The current efforts are focussed on evaluating the risk when the reactor is at mid-loop; this particular POS was selected because of the reduced water inventory and the possible isolation of the loops. The Level 2/3 analyses are conditional on core damage having occurred. Initial results indicate that the conditional consequences can indeed be significant; the defense-in-depth philosophy governing the safety of nuclear power plants is to some extent circumvented because the containment provides only a vapor barrier with no capability for pressure holding, during this POS at Surry. However, the natural decay of the radionuclide inventory provides some mitigation. There are essentially no predicted offsite prompt fatalities even for the most severe releases.