首页> 美国政府科技报告 >Measured Heat Transfer in a Transonic Fan Rig at Casing with Implications on Performance.
【24h】

Measured Heat Transfer in a Transonic Fan Rig at Casing with Implications on Performance.

机译:套管内跨音速风机的传热测量及其对性能的影响。

获取原文

摘要

A highly loaded transonic fan with a splittered rotor and maximum pressure ratio of 2 has been tested at the Naval Postgraduate School. Temperatures on the casing outer wall have been measured using thermocouples in order to assess the heat transfer. An axisymmetric heat transfer analysis has shown that the heat transfer downstream of the rotor through the casing leads to a overstatement of the experimental efficiency by 0.57% and 0.51% for 100% and 90% speed respectively. Just above the rotor is an abradable material that can be considered adiabatic. This heat escapes only aft of the rotor and upstream of the total pressure and total temperature probes. For rotors without an adiabatic casing, the effect would be considerably higher. In addition, heat transfer coefficients have been determined that can be used to assess other compressor applications.