首页> 美国政府科技报告 >Experimental Study of Stack Plume Rise and Dispersion at the Power Station
【24h】

Experimental Study of Stack Plume Rise and Dispersion at the Power Station

机译:电站堆羽升高和扩散的试验研究

获取原文

摘要

This paper describes the primary results of stack plume rise and dispersion experiment at Xu Zhou power station during Nov.-Dec., 1978. Include: (1) Under neutral and near-neutral stratification conditions, the 2/3 power law is the optimizing formula up to date, because of its calculated values in coincidence with observed. (2) Vertical of the buoyant plume from the tall stack is obviously stronger than that of non buoyant plume from the low stack. It is shown that the concept sof Pasquill(1976) model are acceptable, but formula should be modified. (3) From reliable monitoring data of SO2 ground concentration, it is found that the effects of topography and stack height should be comprehensively taken into account in estimating dispersion by gaussian model. (4) It is suggested that in analyzing the stereophoto grammetric data of fluctuating plume, the square deviation of plume distribution should be considered as the sum of two parts--the distribution square deviation of the plume particulates relative to the instantaneous center line of the plume, and the distriubtion square deviaton of the instantaneous center line relative to the average center line of the plume. (5) Lidar is shown to be as effective as steroegraphic method in studying behavior of chimney plumes.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号