Effects of repeated use of tungsten carbide burs on the surface roughness and contact angles of a CAD-CAM PMMA denture base resin

机译:反复使用碳化钨车针对CAD-CAM PMMA假牙基树脂表面粗糙度和接触角的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Statement of problem. The surface roughness (Ra) and wettability of complete denture base materials must meet certain clinical requirements. Although computer-aided design and computer-aided manufacturing (CAD-CAM) systems have recently become popular for the fabrication of complete dentures, the effects of the repeated usage of milling burs on the surface properties of CAD-CAM denture base acrylic resins have not yet been fully investigated. Purpose. The purpose of this in vitro study was to evaluate the effects of new and used burs on the Ra and contact angles (wettability) of a CAD-CAM polymethylmethacrylate (PMMA) denture base material. Material and methods. A total of 40 O2x10-mm disks were fabricated from 1 brand of CAD-CAM PMMA resin (Polident). Half of the specimens (group N) were milled with a new tungsten carbide bur set, while the other half (group U) was milled with a used tungsten carbide bur set. Moreover, half of the specimens (groups NT and UT) were subjected to thermocycling before Ra and contact angle testing. Ra was tested by using a profilometer, and the surfaces were also examined by scanning electron microscopy (SEM). The contact angle was measured by using the sessile drop method. Data were analyzed with the Kruskal-Wallis and Dunn Pairwise Comparison tests (alpha=.05). Results. The mean contact angle was highest for group U (80 degrees) and lowest for group UT (66 degrees) (P<.05). Ra values were highest for group N (1.3 mu m) and lowest for group U (0.93 mu m) (P<.05). Conclusions. Specimens milled with new tungsten carbide burs had lower mean contact angles and higher Ra values than specimens milled with used burs. The contact angles of CAD-CAM PMMA resin specimens milled with used burs decreased significantly after thermocycling. Regardless of whether or not thermocycling was performed, contact angle values decreased as Ra values increased.
机译:问题陈述。全口义齿基材的表面粗糙度(Ra)和润湿性必须满足一定的临床要求。尽管计算机辅助设计和计算机辅助制造 (CAD-CAM) 系统最近在制造全口义齿方面变得流行,但反复使用铣削车针对 CAD-CAM 假牙基丙烯酸树脂表面性能的影响尚未得到充分研究。目的。这项体外研究的目的是评估新旧车针对 CAD-CAM 聚甲基丙烯酸甲酯 (PMMA) 假牙基材的 Ra 和接触角(润湿性)的影响。材料和方法。总共用 1 个品牌的 CAD-CAM PMMA 树脂 (Polident) 制造了 40 个 O2x10 mm 圆盘。一半的试样(N组)用新的碳化钨车针组铣削,而另一半(U组)用用过的碳化钨车针组铣削。此外,一半的试样(NT组和UT组)在Ra和接触角测试之前进行了热循环。使用轮廓仪测试Ra,并通过扫描电子显微镜(SEM)检查表面。采用无柄跌落法测量接触角。使用 Kruskal-Wallis 和 Dunn 成对比较检验 (alpha=.05) 分析数据。结果。U组(80度)的平均接触角最高,UT组(66度)的平均接触角最低(P<.05)。N组的Ra值最高(1.3 μ m)和U组最低(0.93 μ m)(P<.05)。结论。与用旧车针铣削的试样相比,用新碳化钨车针铣削的试样具有更低的平均接触角和更高的 Ra 值。用旧车针铣削的CAD-CAM PMMA树脂试样在热循环后接触角显著减小。无论是否进行热循环,接触角值都随着Ra值的增加而减小。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号