...
首页> 外文期刊>Clean Energy >Wind energy conversion system using perturb observe-based maximum power point approach interfaced with T-type three-level inverter connected to grid
【24h】

Wind energy conversion system using perturb observe-based maximum power point approach interfaced with T-type three-level inverter connected to grid

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

The performance of a permanent magnet synchronous generator (PMSG)-based wind energy conversion system (WECS) supplied to an uncontrolled rectifier-fed boost converter (BC) interfaced with a three-phase T-type three-level inverter (TLI) has been analysed. This approach ensures maximum power for varying wind speeds, and the total harmonic distortion of the T-type TLI grid current value is 3.18. In this paper, the performance of a permanent magnet synchronous generator (PMSG)-based wind energy conversion system (WECS) supplied to an uncontrolled rectifier-fed boost converter (BC) interfaced with a three-phase T-type three-level inverter (TLI) has been analysed. The proposed WECS involves three converters, namely an uncontrolled rectifier that is used for conversion from AC to DC; a BC supplied by a PMSG-fed rectifier used to enhance the voltage gain; and a grid-connected three-phase T-type TLI is proposed to eliminate power-quality issues with synchronization of grid voltage and current. The main goal of this research is to model and control the grid-connected T-type TLI using a d-q synchronous frame for wind energy for regulating the DC-link voltage and transferring the generated wind power from the BC to the grid. Furthermore, the perturb observe (PO)-based maximum power point (MPP) approach is recommended to keep track of the MPP for a BC that is supplied from a PMSG-based WECS under constant and variable wind speeds. The proposed PMSG-based WECS interfaced with grid-connected T-type TLI using d-q control has been computationally modelled, simulated and validated with constant and variable speeds using MATLAB (R) and Simulink (R). It is confirmed that the PO-based MPP approach ensures maximum power for varying wind speeds, and the total harmonic distortion of the T-type TLI grid current value is 3.18, which is within IEEE-519 limits. Furthermore, with grid synchronization, the power factor of the T-type TLI is maintained at unity to avoid power-quality issues.

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号