首页> 外文期刊>Der Unfallchirurg >Reconstruction of bone defect by vascularized fibular transfer after failed wrist arthroplasty
【24h】

Reconstruction of bone defect by vascularized fibular transfer after failed wrist arthroplasty

机译:腕关节置换术失败后通过血管化腓骨转移重建骨缺损

获取原文
获取原文并翻译 | 示例

摘要

A bone defect of 14 cm resulted after wrist implant removal because of loosening in a 46-year-old patient. Performing wrist arthrodesis the defect was reconstructed by a vascularized fibular transfer. Solid bone fusion was complete in six weeks. Free function of the digits was seen because of length reconstruction.
机译:一名 46 岁的患者在手腕植入物移除后因松动而导致 14 cm 的骨缺损。进行腕关节融合术,通过血管化腓骨转移重建缺损。实体骨融合在六周内完成。由于长度重建,可以看到数字的自由功能。