【24h】

CT evaluation of upper thoracic spine for surgical application of transarticular screw placement

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: Although pedicle screw fixation has been increasingly used in the upper thoracic spine in recent years, controversies exist about the safety and complications such as nerve or vascular intrusion associated with the technique. In this study, an alternative method of transarticular screw fixation was validated. Materials and methods: Morphometric analysis was performed on computed tomography (CT) scans of the upper thoracic zygapophysial joints of C7, T1, T2 and T3 in 20 male and 20 female patients in the axial and sagittal planes. The degree of screw angulation was recorded in the sagittal and axial planes and the screw length was measured at the spinal level from C7 to T3. Results: The smallest medial-lateral diameter and anterior-posterior diameter of IAP was found at T3 in the female patients and C7 in the male patients. The screw trajectory length ranged from 14.9 to 20.5 mm in all patients. All the above measurements were significantly different between male and female patients at all levels (P0.05) between male and female patients in the axial and sagittal angles. Conclusion: The morphometric data of C7-T3 zygapophysial joints indicate the suitable screw diameter and screw length for this technique. Transarticular screw fixation proved to be a potentially safe alternative to pedicle screw fixation in this region.

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号