首页> 外文期刊>Veterinary Radiology & Ultrasound >REPEATABILITY AND RELIABILITY OF GLOMERULAR FILTRATION RATE DETERMINATION VIA GAMMA CAMERA UPTAKE OF TC-99M-DTPA IN CATS WITH CHRONIC KIDNEY DISEASE
【24h】

REPEATABILITY AND RELIABILITY OF GLOMERULAR FILTRATION RATE DETERMINATION VIA GAMMA CAMERA UPTAKE OF TC-99M-DTPA IN CATS WITH CHRONIC KIDNEY DISEASE

机译:通过伽马相机摄取 TC-99M-DTPA 测定慢性肾病猫肾小球滤过率的可重复性和可靠性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Measurement of glomerular filtration rate (GFR) via gamma camera uptake of 99mTc-diethylenetriaminepentaacetic acid is a standard method for quantifying renal function. Aims of this retrospective, observer agreement study were to determine intra-and interobserver variation in GFR values for cats with chronic kidney disease and to determine whether renal insufficiency classification changed between observers. Guideline cut-points were established for the difference in repeated GFRs to differentiate changes caused by therapeutic effect vs. inherent variation. Included cats had a diagnosis of chronic kidney disease and had undergone GFR examinations between the years of 2010 and 2013. Twenty-nine GFR studies were sampled. Each study was read twice, 6 months apart, by two veterinary radiologists and one radiology resident. Modified Bland-Altman plots were used to investigate differences between readings 1 and 2 by observer and between pairs of observers by reading. Reliability of clinical classification was assessed through comparisons between readings and observers. Measurements were not systematically different between readings for the experienced observers but were higher in reading 1 than reading 2 for the inexperienced observer. Measurements were not systematically different between the experienced observers in reading 1 or between any two observers in reading 2. Reliability for GFR measurements was high among experienced observers; variations in GFR measurements rarely led to differences in clinical classification. Results suggested that, for experienced observers, changes in GFR values following treatment in cats with chronic kidney disease between -0.4 and 0.4 mL/min/kg may be due to inherent variability rather than treatment effect. (C) 2016 American College of Veterinary Radiology.
机译:通过伽马相机摄取 99mTc-二乙烯三胺五乙酸测量肾小球滤过率 (GFR) 是量化肾功能的标准方法。这项回顾性、观察者协议研究的目的是确定患有慢性肾病的猫的 GFR 值的观察者内和观察者间变化,并确定观察者之间的肾功能不全分类是否发生变化。为重复 GFR 的差异建立了指南切点,以区分由治疗效果引起的变化与固有变化。包括的猫被诊断为慢性肾病,并在 2010 年至 2013 年间接受了 GFR 检查。抽样了29项GFR研究。每项研究由两名兽医放射科医生和一名放射科住院医师阅读两次,间隔 6 个月。修改后的 Bland-Altman 图用于研究观察者读数 1 和 2 之间的差异以及通过阅读研究观察者对之间的差异。通过读数和观察者之间的比较来评估临床分类的可靠性。有经验的观察者的读数之间的测量值没有系统性差异,但对于没有经验的观察者来说,读数 1 的测量值高于读数 2。在阅读1中,有经验的观察者之间或在阅读2中,任何两个观察者之间的测量结果没有系统性差异。在有经验的观察者中,GFR测量的可靠性很高;GFR测量值的差异很少导致临床分类的差异。结果表明,对于有经验的观察者来说,慢性肾病猫治疗后 GFR 值的变化在 -0.4 和 0.4 mL/min/kg 之间可能是由于固有的变异性而不是治疗效果。(C) 2016 年美国兽医放射学会。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号