首页> 外文期刊>International Journal of Refrigeration >Experimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysis
【24h】

Experimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysis

机译:热级联式Ranque-Hilsch涡流管性能的实验研究和火用分析

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, three Ranque-Hilsch vortex tubes were used, which have 9 mm inside diameter and length/diameter ratio was 15. Their performances were examined as one of the classical RHVT and other was hot cascade type RHVT. Performance analysis was according to temperature difference between the hot outlet and the inlet (ΔT_(hot.)). The ΔT_(hot) values of hot cascade type Ranque-Hilsch vortex tubes were greater than the ΔT_(hot) values of classical RHVT, which were determined experimentally. The total inlet exergy, total outlet exergy, total lost exergy and exergy efficiency of hot stream were investigated by using experimental data. In both the classical RHVT and hot cascade type RHVT, it was found that as fraction of cold flow increases the total lost exergy decreases. It was also found that, the hot cascade type RHVT more exergy efficiency of hot outlet than the classical RHVT. Excess ΔT_(hot) value of hot cascade type Ranque-Hilsch vortex tube causes the excess exergy efficiency of hot outlet.
机译:在这项研究中,使用了三个Ranque-Hilsch涡流管,它们的内径为9 mm,长径比为15。作为经典的RHVT之一,其性能已得到检验,另一类是热级联式RHVT。根据热出口和入口之间的温差(ΔT_(hot。))进行性能分析。热级联式Ranque-Hilsch涡流管的ΔT_(hot)值大于经典RHVT的ΔT_(hot)值,这是通过实验确定的。利用实验数据研究了热流的总入口火用,总出口火用,总损失火用和火用效率。在经典RHVT和热级联式RHVT中,都发现随着冷流量比例的增加,总的失火能值降低。还发现,热级联式RHVT比传统RHVT更有效率。热级联式Ranque-Hilsch涡流管的过剩ΔT_(hot)值会导致热出口的过剩效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号