首页> 外文期刊>journal of applied physics >Field‐emission liquid‐metal ion source and triode ion gun
【24h】

Field‐emission liquid‐metal ion source and triode ion gun

机译:场连字符;发射液体连字符;金属离子源和三极管离子枪

获取原文
获取外文期刊封面目录资料

摘要

A pointed‐filament‐type field‐emission liquid‐metal ion source is designed and employed as a gold ion source. By adding a crossbar across a hairpin bend, the amount of the gold adhering on the filament is increased. The lifetime is estimated to be over 200 h at 10‐mgr;A emission current. The emission current increases with increasing extraction voltage up to a saturation value which is ascribed to a limitation of the supply of liquid gold to the needle apex. The value of current density per unit solid angle is 30 mgr;A/sr at a total current of 30 mgr;A, which is of the same order as that obtained from a gallium ion source previously reported. Emission current fluctuations of a few tens of percent of the dc component are observed. In order to regulate the emission current and suppress current fluctuations, a bias electrode in addition to a counterelectrode is placed close to the needle apex. With such a triode structure, the emission current is regulated by a bias voltage of several hundred volts and stabilized to within 1 by means of feedback to the bias voltage of a current monitor output.
机译:设计并采用尖头&连字符;细丝&连字符型场&连字符发射液体&连字符;金属离子源作为金离子源。通过在发夹弯处添加横杆,可以增加粘附在灯丝上的金量。在 10‐&mgr;A 发射电流下,寿命估计超过 200 小时。发射电流随着萃取电压的增加而增加,直至达到饱和值,这归因于向针顶供应液态金的限制。当总电流为30 &mgr;A时,每单位立体角的电流密度值为30 &mgr;A/sr,这与先前报道的从镓离子源获得的电流密度值相同。观察到直流分量的几百分之几十的发射电流波动。为了调节发射电流并抑制电流波动,除了反电极外,还放置在靠近针尖的偏置电极。在这种三极管结构下,发射电流由几百伏的偏置电压调节,并通过反馈到电流监视器输出的偏置电压稳定在1%以内。

著录项

  • 来源
    《journal of applied physics》 |1981年第4期|2642-2645|共页
  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号