The spherical acoustic resonator is a remarkably accurate and convenient tool for the measurement of thermophysical properties of gases at low and moderate densities. The speed of sound (c) in a gas of interest can be measured with an accuracy of 0.02percnt; merely by measuring the frequencies of the radial resonances when the resonator is filled with the gas of interest and then repeating the frequency measurements with a reference gas such as argon. The resonance frequencies of the radial modes are easily measured because these modes have very highQrsquo;s, typically 2000ndash;10thinsp;000. In this work the precision and accuracy of speed of sound measurements have been substantially improved by including a detailed acoustic model of the resonator in the analysis. Many of the important parameters of the model can be determined from acoustic measurements: Painstaking mechanical measurements are not required. We have used a spherical resonator to measure the speed and attenuation of sound in C2H4in the temperature range 0ndash;100thinsp;deg;C and the pressure range 0.15ndash;1.0 MPa. Our measured values ofcin C2H4have a precision of 0.003percnt; and agree with those of Gammon within the scatter of Gammonrsquo;s data (plusmn;0.02percnt;). This agreement is remarkable when one considers that our spherical resonator is operated in the frequency range 4ndash;13 kHz while Gammon has used a more conventional, cylindrical, variable path, acoustic interferometer operating at 500ndash;2500 kHz. To attain this agreement, we did not have to make any highly accurate measurements other than frequency. Our measured values of the bulk relaxation frequency of C2H4are within the scatter of the more recent values of the literature. In the course of our rsquo;rsquo;calibrationrsquo;rsquo; measurements with argon we have redetermined the leading acoustic virial coefficient of argon. Our values for the virial are in satisfactory agreement with those in the literature. We include several practical suggestions for increasing the accuracy and/or versatility of spherical resonators.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号