首页> 外文期刊>Journal of environmental & engineering geophysics >Induced Polarization and Resistivity of Second Potential Differences (SPD) with Focused Sources Applied to Environmental Problems
【24h】

Induced Polarization and Resistivity of Second Potential Differences (SPD) with Focused Sources Applied to Environmental Problems

机译:聚焦源的感应极化和二电位差电阻率(SPD)应用于环境问题

获取原文
获取原文并翻译 | 示例

摘要

A novel technique is proposed to improve shallow induced polarization (IP) and resistivity survey results. We propose the apparent resistivity and apparent chargeability of second potential differences (SPD), employing two focused sources (FS) mathematically manipulated by superposition. To test the idea, a synthetic model is developed with two bodies. The first body is a small shallow heterogeneity which is above the second and larger body. This synthetic model illustrates the shape and response of the apparent resistivity and chargeability for FS under the random noise and masking effect. These processes reduce electromagnetic coupling, telluric noise, contamination in channel links, and small heterogeneous responses. A field test of the SPD for FS was carried out in an agricultural site irrigated with wastewater, where contaminated water laden with metals has been accumulating for years in the soil. Soil samples were collected and analyzed throughout the geophysical survey to correlate the resistivity-IP results. Soil laboratory analysis included metal content, moisture content and texture. The parameters computed after applying the SPD for FS depicted a better lateral resolution where vertical and horizontal boundaries of the anomaly zones were well defined. It was possible to determine the low permeability horizontal layer made of clay-soil (called tepetate), which is a barrier for water and metals.
机译:提出了一种新的技术来改善浅诱导极化(IP)和电阻率测量结果。我们提出了第二电位差(SPD)的视电阻率和表观电荷率,采用两个通过叠加进行数学操纵的聚焦源(FS)。为了验证这个想法,开发了一个具有两个主体的合成模型。第一个主体是一个小的浅层异质性,它高于第二个和较大的主体。该合成模型说明了随机噪声和掩蔽效应下FS视电阻率和带电率的形状和响应。这些过程减少了电磁耦合、大地噪声、信道链路中的污染和小的异构响应。在一个用废水灌溉的农业场地进行了FS的SPD现场测试,其中含有金属的污染水已经在土壤中积聚了多年。在整个地球物理调查过程中收集和分析土壤样品,以关联电阻率-IP结果。土壤实验室分析包括金属含量、水分含量和质地。应用FS的SPD后计算的参数描绘了更好的横向分辨率,其中异常区的垂直和水平边界得到了很好的定义。可以确定由粘土(称为tepetate)制成的低渗透性水平层,这是水和金属的屏障。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号