首页> 外文期刊>Nuclear Technology: A journal of the American Nuclear Society >MAXIMUM HEAT TRANSFER TO METALLIC-LIQUID FLOWS FROM A CLUSTER OF VERTICAL, PARALLEL-PLATE CHANNELS HEATED SYMMETRICALLY
【24h】

MAXIMUM HEAT TRANSFER TO METALLIC-LIQUID FLOWS FROM A CLUSTER OF VERTICAL, PARALLEL-PLATE CHANNELS HEATED SYMMETRICALLY

机译:MAXIMUM HEAT TRANSFER TO METALLIC-LIQUID FLOWS FROM A CLUSTER OF VERTICAL, PARALLEL-PLATE CHANNELS HEATED SYMMETRICALLY

获取原文
获取原文并翻译 | 示例
       

摘要

The problem of optimizing a cluster of isothermal or isoflux parallel-plate channels where the coolant is a metallic liquid is addressed. The pressure difference is fixed, and laminar forced convection is caused by the simultaneous development of velocity and temperature from free-stream conditions of the liquid, The Fanning friction factor is invariant with the fluid. However, local and streamwise-mean Nusselt number distributions for each heating condition are carefully computed exploiting the physical analogy between transient conduction in a flat plate and steady temperature development inside a parallel-plate channel under the premise of slug flow. The qualitative influence of diminute Prandtl number liquids (Pr = 0.01 and 0.005) is reported in terms of the optimal heat transfer and the optimal plate-to-plate spacing for the two heating conditions employed. References: 7