首页> 外文期刊>journal of liquid chromatography >Influence of Temperature on the Response of Differential Refractometer for Quantitative Analysis in High-Performance Liquid Chromatography
【24h】

Influence of Temperature on the Response of Differential Refractometer for Quantitative Analysis in High-Performance Liquid Chromatography

机译:Influence of Temperature on the Response of Differential Refractometer for Quantitative Analysis in High-Performance Liquid Chromatography

获取原文
           

摘要

Some of commercially available RI detectors are thermostated, so as to keep the base-line drift minimum. However, for quantitative analysis, care must be taken to control the difference of temperature (#x394;t) of a liquid in a sample cell (ts) and that in a reference cell (tr), because the variation of the response of a RI detector is a function of #x394;t. Even tsis equal to tr, or #x394;t is constant through the period of the experiments, tsat determination (td) of samples must be the same to that at calibration (tc) with standards, because the variation of the RI response is also a function of #x394;t#x2032; (=td- tc). The smaller is the difference of the refractive indeces of a solute and the mobile phase and the larger is the difference of the temperature coefficients of a solute and the mobile phase, the more serious is the influence of the temperature differences. Calculated and observed results for the influence of temperature are demonstrated.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有