首页> 外文期刊>archives of orthopaedic and trauma surgery >Micromotions in the primary fixation of cementless femoral stem prostheses
【24h】

Micromotions in the primary fixation of cementless femoral stem prostheses

机译:无骨水泥股骨干假体一期固定中的微动

获取原文
获取外文期刊封面目录资料

摘要

Thirty cementless femoral stems of six different types of hip endoprostheses were impanted in femurs taken at autopsy and underwent static loading and afterwards dynamic loading of 50000 cycles to simulate walking during the early months after implantation. After that, the static load tests were performed again. During both static load series a certain amount of micromotion between stem and implantation bed occurred in the frontal and sagittal planes and also during rotation. The six prostheses exhibited clearly differing results. The influence of dynamic load on the extent of micromotion was small.
机译:将 6 种不同类型髋关节内假体的 30 根无骨水泥股骨干插入尸检时采集的股骨中,并接受静态负荷和随后 50000 次循环的动态负荷,以模拟植入后最初几个月的行走。之后,再次进行静载荷测试。在两个静载荷序列中,茎和植入床之间在额面和矢状面以及旋转过程中都发生了一定程度的微运动。这六个假肢表现出明显不同的结果。动态载荷对微动程度的影响较小。