首页> 外文期刊>archives of orthopaedic and trauma surgery >Prostaglandin E2level in tissue surrounding aseptic failed total hips
【24h】

Prostaglandin E2level in tissue surrounding aseptic failed total hips

机译:无菌性衰竭的全髋关节周围组织中的前列腺素 E2 水平

获取原文
获取外文期刊封面目录资料

摘要

Production of inflammatory mediators (IM) by cells and specifically macrophages around loosened implants may be responsible for their loosening. Our hypothesis was that different materials give rise to different amounts of these IM. It is thought that alumina/alumina for total hip replacement (THR), which has been used for 15 years in our orthopedic department, may produce less IM than other systems. We initiated a clinical prospective study to measure the level of prostaglandin E2(PGE2) in tissue surrounding loosened prostheses to quantify PGE2production regarding the types of material involved in the friction couple, i.e., alumina/alumina versus metal/polyethylene, and the type of fixation, i.e., cemented versus cementless. A total of 29 THR revisions were performed in 28 patients. Four implant groups were identified: alumina/alumina cemented, alumina/alumina cementless, metal/polyethylene cemented, and metal/polyethylene cementless. For each revision, tissues surrounding the failed implants were harvested and processed, and the PGE2was measured in a blind manner using an immunoassay technique. As the measuring technique was difficult, at least three determinations for each sample were necessary. Some samples were excluded from the analysis for various reasons, for example, second or further revisions involving many different materials in the past, conjunction of metallic and alumina debris and samples taken from nonloosened components. Finally, 15 samples were considered adequate for inclusion in this study. Two groups were analyzed and compared: the alumina/alumina couple and the metal/polyethylene couple. Tissue surrounding the first group demonstrated a PGE2level of 69 ± 56 fmol/mg wet weight compared to 202 ± 156 fmol/mg for the second. The Wilcoxon test was applied, and there was a statistical difference (P<0.05). When the alumina/alumina cemented group was compared to the alumina/alumina cementless group, there was a tendency to less PGE2with the cemented, but the difference was not statistically significant. Results thus demonstrate that alumina/alumina produces less IM than metal/polyethylene. However, these results do not indicate whether this is related to the type of debris, the amount, or both. This remains a preliminary study. Further studies with more samples, other mediators and growth factors, and a precise comparison to histological findings are still necessar
机译:松动植入物周围的细胞,特别是巨噬细胞产生炎症介质 (IM) 可能是导致其松动的原因。我们的假设是,不同的材料会产生不同数量的这些IM。据认为,在我们的骨科已经使用了 15 年的氧化铝/用于全髋关节置换术 (THR) 的氧化铝/氧化铝可能比其他系统产生更少的 IM。我们启动了一项临床前瞻性研究,以测量松动假肢周围组织中前列腺素 E2 (PGE2) 的水平,以量化摩擦偶中涉及的材料类型的 PGE2 产生,即氧化铝/氧化铝与金属/聚乙烯,以及固定类型,即胶合与无胶合。共对 28 例患者进行了 29 次 THR 翻修。确定了四个植入物组:氧化铝/氧化铝胶结、氧化铝/氧化铝无水泥、金属/聚乙烯胶结和金属/聚乙烯无水泥。对于每次翻修,收集和处理失败植入物周围的组织,并使用免疫测定技术以盲法方式测量 PGE2。由于测量技术很困难,因此需要对每个样品进行至少三次测定。由于各种原因,一些样品被排除在分析之外,例如,过去涉及许多不同材料的第二次或进一步修订,金属和氧化铝碎片的结合以及从未松动部件中取出的样品。最后,15个样本被认为足以纳入本研究。对两组进行了分析和比较:氧化铝/氧化铝对和金属/聚乙烯对。第一组周围的组织显示 PGE2 水平为 69 ± 56 fmol/mg 湿重,而第二组为 202 ± 156 fmol/mg。采用Wilcoxon检验,差异有统计学意义(P<0.05)。将氧化铝/氧化铝胶结组与氧化铝/氧化铝无水泥组进行比较时,与胶结组相比,PGE2有减少的趋势,但差异无统计学意义。因此,结果表明,氧化铝/氧化铝产生的IM比金属/聚乙烯少。然而,这些结果并不能表明这是否与碎片的类型、数量或两者有关。这仍然是一项初步研究。仍然需要对更多样本、其他介质和生长因子进行进一步研究,并与组织学结果进行精确比较

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号