Development of a Personal Sampler for Collecting Fungal Spores

机译:Development of a Personal Sampler for Collecting Fungal Spores

获取原文
获取原文并翻译 | 示例
       

摘要

Exposure to fungal aerosols is of concern in indoor environments.However,sampling limitations have previously made it difficult to assess exposures accurately,especially long-term exposures.A prototype personal aerosol sampler,based on cyclone principles and using a 1.5 ml microcentrifuge tube as a particle collection receptacle has been designed and fabricated.Collection efficiency for aerosol particles in the size range of fungal spores has been evaluated for different types of microcentrifuge tubes,together with the effect of a polyethylene glycol coating on the inside of the tube and the effect of adding water to the tube.Monodisperse,fluorescently tagged polymer microspheres with median diameters of 0.5,1,2,3,6,11,and 16 mum were used to evaluate sampler performance with particle diameter.The microcentrifuge-tube sampler was tested at flow rates of 2 and 4 liters per minute (1/min).Experimental results indicate that the microcentrifuge-tube sampler has an aspiration efficiency of 100 in calm air for particles up to 16 mum.At 41/min,the microcentrifuge-tube sampler is able to collect nearly 100 of particles greater than 3 mum and >90 of particles between 2.5 and 3 mum.The 50 cutoff size is 1.5 mum.The performance of the sampler did not vary with the different brands of tubes tested or with the presence or absence of a coating on the tube surface.Furthermore,the addition of water to the tube resulted in a slight increase in collection efficiency.A sampling time of 5 h was feasible at 45-50 relative humidity before evaporation led to significant water loss.The cutoff size of 1.5 mum is comparable to many commercially available bioaerosol samplers.Besides being easy to use,simple to fabricate,and inexpensive,this novel sampler has several advantages over conventional samplers: long-term samples are possible (the limitation of impaction methods);there is no sample transfer loss since the transfer step has been eliminated (the limitation of filter cassettes);laboratory analyses are not dependent solely upon a single analysis method (the limitation of impaction methods),and there is no sampler adherence loss (the limitation of trying to wash microorganisms from filters).In addition,use of the sampler would be applicable in a variety of occupational settings from low bioaerosol concentrations (i.e.,indoor environments) to high bioaerosol concentrations (i.e.,agricultural setting) by varying sampling time periods and using sensitive analytical methods.

著录项

  • 来源
  • 作者单位

    Health Effects Laboratory Division,National Institute for Occupational Safety and Health (NIOSH),Centers for Disease Control and Prevention,Morgantown,West Virginia;

    Division of Applied Research and Technology,National Institute for Occupational Safety and Health (NIOSH),Centers for Disease Control and Prevention,Morgantown,West Virginia;

    Division of Respiratory Disease Studies,National Institute for Occupational Safety and Health (NIOSH),Centers for Disease Control and Prevention,Morgantown,West Virginia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类 混合与搅拌过程;
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号