Deactivating metal particle by optimizing insulation configuration in spark gap switch

机译:Deactivating metal particle by optimizing insulation configuration in spark gap switch

获取原文
获取原文并翻译 | 示例
           

摘要

As a new method to protect the spark gap from metal particle contamination, the effect of the metal inserted insulator on the controlling behavior of metal particles was investigated in a quasi-uniform electric field. Considering that the inserted metal electrodes can decrease the electric field around the insulator and divert the electrostatic force away from the insulator, the method can be used to prevent the particles from moving toward the insulator so as to reduce the possibility of a breakdown. The inserted metal electrodes can reverse the direction of the particles' horizontal motion. A study on the insulator shape indicates that the inserted metal electrodes can repulse the particle and improve the particle lifting voltage significantly near the vertical surface of the insulator or ribbed insulator. For the insulator with a tilting surface the inserted metal electrodes have little influence on the particle motion. In addition, the size of the inserted electrodes shows a significant effect on the control of particle motion.