首页> 外文期刊>Progress in nuclear engergy >CFD analysis on subcooled boiling phenomena in PWR coolant channel
【24h】

CFD analysis on subcooled boiling phenomena in PWR coolant channel

机译:CFD analysis on subcooled boiling phenomena in PWR coolant channel

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Eulerian two-fluid model coupled with wall boiling model was employed to calculate the three dimensional flow field and heat transfer characteristics in a hot channel with vaned spacer grid in PWR. The heat transfer from pellet-gap-cladding to coolant was also taken into account by a system coupled code MpCCI. The wall boiling model utilized in this study was validated by Bartolomei experiment data, and a good agreement can be observed. By solving the governing equation in a two-way coupled method, the distribution of temperature in the pellet-gap-cladding region and the distribution of temperature, void fraction and velocity of two-phase flow in coolant channel can be obtained. The influences of spacer grid and mixing vane on the thermal-hydraulic characteristics were analyzed. The heat transfer capacity was strongly improved by the spacer grid and mixing vane, while the flow resistance was also enlarged. Localized volume fraction of vapor phase decreased due to mixing vane, which will decrease the possibility of the departure from nucleate boiling (DNB) and increase the critical heat flux (CHF). By analyzing the temperature and void fraction at cladding outer surface, the critical regions where hot spot may occur were determined. (C) 2015 Elsevier Ltd. All rights reserved.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号