MRI after unicondylar knee arthroplasty: Rotational alignment of components

机译:单髁膝关节置换术后的 MRI:组件的旋转对齐

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Introduction: This pilot study used magnet resonance imaging (MRI) to analyse the rotation of medial unicondylar knee arthroplasty (UKA) components and assessed how accurately the results could be reproduced. Materials and methods: Knee MRI using a special protocol to reduce metal artefact was performed in ten patients who had undergone medial UKA. Two independent investigators measured the rotation angle of femoral (zirconium) and tibial (cemented full-poly or cemented modular metal-backed) components applying different reference lines for the latter. Statistical analysis comprised tests for reliability, variance between measurement techniques, standard deviations and limits of agreement. Results: For all methods tested, there was sufficient inter- and intra-observer reliability. Lowest variances were, however, found for the femoral epicondyles, for both femoral and tibial components. A tangent to the dorsal epicondyles of the tibia also gave reproducible results with low variances for the tibial component. Discussion: Almost all applied measurement techniques were reproducible by statistical definition, although some of them resulted in substantial differences between both, observations and observers. A variance test helps to distinguish better between clinically useful and less accurate references. Conclusion: MRI allows good reproducible rotation analysis via the femoral epicondyles for both femoral and tibial UKA implants. For the tibia, the tibial tuberosity, the eminentia and the tibial epicondyles in particular were shown to be less reliable. The dorsal epicondyles seem to be most suitable for the tibial component.
机译:简介:这项初步研究使用磁共振成像 (MRI) 来分析内侧单髁膝关节置换术 (UKA) 组件的旋转,并评估结果的再现准确性。材料和方法:在10名接受过内侧UKA的患者中,使用特殊方案进行膝关节MRI以减少金属伪影。两名独立研究人员测量了股骨(锆)和胫骨(胶合全聚乙烯或胶合模块化金属背衬)组件的旋转角度,对后者应用了不同的参考线。统计分析包括对可靠性、测量技术之间的差异、标准偏差和一致性限度的检验。结果:对于所有测试的方法,观察者间和观察者内都有足够的可靠性。然而,股骨上髁、股骨和胫骨成分的方差最小。与胫骨背上髁的切线也给出了可重复的结果,胫骨成分的方差很小。讨论:几乎所有应用的测量技术都可以通过统计定义重复,尽管其中一些导致观察者和观察者之间存在实质性差异。方差检验有助于更好地区分临床有用和不太准确的参考文献。结论:MRI 允许通过股骨上髁对股骨和胫骨 UKA 植入物进行良好的可重复旋转分析。对于胫骨,特别是胫骨粗隆、隆起和胫骨上髁被证明不太可靠。背上髁似乎最适合胫骨部分。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号