首页> 外文期刊>The Journal of Laryngology and Otology >Rapid-prototyped temporal bone and inner-ear models replicated by adjusting computed tomography thresholds.
【24h】

Rapid-prototyped temporal bone and inner-ear models replicated by adjusting computed tomography thresholds.

机译:Rapid-prototyped temporal bone and inner-ear models replicated by adjusting computed tomography thresholds.

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: This study aimed to investigate the validity of adjusting computed tomography thresholds in order to replicate a temporal bone model suitable for dissection training and education. MATERIALS AND METHODS: A simulated three-dimensional model of a human temporal bone was prototyped using selective laser sintering. The powder layers were laser-fused, based on detailed computed tomography data, and accumulated to create a three-dimensional structure. The computed tomography threshold value of the stapes was modified on standard triangular language file in order to replicate the stapes. The intensity value was determined to select the fluid lumen of the inner ear and the bone surface, in order to replicate the inner ear. RESULTS: The model could be shaved, using surgical instruments, in the same manner as during real surgery. The stapes could be reproduced, making this model even more realistic than a previous version. The inner ear was recreated, along with the surrounding bony wall and the ossicles. CONCLUSION: This model facilitates dissection training and easy understanding of the relation between the labyrinth and the surrounding structures.