Influence of relative humidity on analyzing electric field exposure using ELF electric field measurements

机译:Influence of relative humidity on analyzing electric field exposure using ELF electric field measurements

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The objective of the study was to investigate the influence of humidity on analyzing electric field exposure using extremely low frequency (ELF) electric field measurements. The study included 322 measurements in a climate room. We used two commercial three-axis meters, EFA-3 and EFA-300, and employed two measurement techniques in the climate room where we varied the temperature from 15 to 25°C, the relative humidity from 55 to 95, and the electric field from 1 to 25kV/m. We calculated Pearson correlations between humidity and percentage errors for all data and for data at different levels of humidity. When the relative humidity was below 70, the results obtained by the different measurement methods in terms of percentage errors were of the same order of magnitude for the considered temperatures and field strength, but the results were less reliable when the relative humidity was higher than 80. In the future, it is important to take humidity into account when electric field measurement results will be compared to the values given in different exposure guidelines.