【24h】

DC Breakdown Strength of Polypropylene Films: Area Dependence and Statistical Behavior

机译:DC Breakdown Strength of Polypropylene Films: Area Dependence and Statistical Behavior

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The dc breakdown strengths of 4-15 μm thick capacitor grade polypropylene (PP) films were determined. The measurements were performed with an automatic measurement system using five electrodes with areas between 0.045 and 9.3 cm{sup}2. Some samples were studied with larger electrodes. Samples were not aged but were measured as received. The measurements were performed in air at room temperature and typically 40-80 breakdowns per sample per electrode area were collected. The Weibull distribution parameters α and β were fitted to the data. Depending on the electrode area and the film grade, the α-parameter values obtained were between 450 and 850 V/μm. The breakdown strength values showed decreasing area dependence with decreasing electrode area and the Weibull scaling law was not valid for the smallest electrode areas. The α-values for the large sample areas were extrapolated from the small area data by area and Weibull extrapolation. The area extrapolation overestimated the breakdown strength at 4 m{sup}2 by 40-50 whereas the Weibull extrapolation gave an accuracy of ±15. The extrapolated breakdown strengths for the full-scale power capacitors deviated from the capacitor manufacturers test data. This indicated that different defect distributions were responsible for the breakdown strengths in the oil impregnated power capacitors than in the small dry film samples.