AbstractThis article deals with data treatment problems associated with the estimation of the combined distribution of molecular weights and chemical composition in linear copolymers by size exclusion chromatography, when correction for instrumental broadening is considered. Standard dual detection is assumed, i.e., the chromatograph is fitted with a “universal” detector (a differential refractometer) and a specific sensor to one comonomer only (a UV spectrophotometer). A real and a “synthetic” example (involving the analysis of a diblock styrene–butadiene rubber) are presented. Also, a propagation of errors study associated with the deconvolution operations is developed. It is concluded that the best calculation procedure is to first compute the combined distributions from the raw chromatograms and then correct such distributions for instrumental broadening. © 1992 John Wiley
机译:摘要本文探讨了在考虑仪器展宽校正时,通过尺寸排阻色谱法估计线性共聚物中分子量和化学成分的组合分布相关的数据处理问题。假设采用标准的双重检测,即色谱仪配备一个“通用”检测器(差示折光仪)和一个仅针对一个共聚单体的特定传感器(紫外分光光度计)。给出了一个真实和“合成”的例子(涉及二嵌段苯乙烯-丁二烯橡胶的分析)。此外,还开发了与反卷积运算相关的误差传播研究。结论是,最好的计算程序是首先从原始色谱图中计算组合分布,然后校正这些分布以进行仪器展宽。© 1992 约翰·威利