首页> 外文期刊>ASHRAE Transactions >Determining Cooling Loads in Health Care Clinical Spaces Using Historical Data
【24h】

Determining Cooling Loads in Health Care Clinical Spaces Using Historical Data

机译:Determining Cooling Loads in Health Care Clinical Spaces Using Historical Data

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

As more buildings are connected to cloud-based large data systems, there is an opportunity to learn from the data. Predictive load and energy modeling calculations, which have long been performed based on assumptions, can be validated, or adjusted based on accrued data from in-service buildings. This paper publishes zone sensible cooling loads, based on historical data. The results should serve as a guideline to cooling load and energy modeling calculations in future designs. The data assessed includes room temperature, supply temperature, and airflow, collected on 5-minute intervals for one year of operation. Data assessed is limited to the cooling hours between 8 AM to 6 PM, May through October. Sensible load was calculated for each hour using the difference in temperature, multiplied by the airflow. Zones are classified into Zone Type, based on the room name where the thermostat resides. Toads are nonnalized to zone area. The results include (1) cooling loads for the 75, 50, 25, 2, and 0.4 exceedance values, and (2) diversity factors indicating the maximum simultaneously occurring load in multiple zones of the same type.