首页> 外文期刊>Kerntechnik >Experimental study on direct contact condensation of saturated steam at low mass flux in subcooled quiescent water
【24h】

Experimental study on direct contact condensation of saturated steam at low mass flux in subcooled quiescent water

机译:Experimental study on direct contact condensation of saturated steam at low mass flux in subcooled quiescent water

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract The phenomenon of saturated steam jet injection in subcooled quiescent water has many practical applications including in heat exchangers, steam jet pumps, steam dumping systems in nuclear plants, etc. The experimental setup is designed and fabricated indigenously to investigate this phenomenon at lower mass fluxes ~120 and 150?kg/m2?s. The steam jet of conical shape has been observed for all the test conditions. The recorded axial temperature distribution showed that near the nozzle region, the temperature is governed by the saturated condition of steam while the later region is dependent on the water pool temperature. The maximum temperature is observed to be at the center of the jet. It has been found that the dimensionless penetration length of the steam jet in water is directly dependent on both the temperature of the water pool and the mass flux of steam. The dimensionless jet length has been found in the range ~1.54–2.02 and 2.07–2.19 for mass fluxes ~120 and 150?kg/m2?s, respectively. The average heat transfer coefficient has been found in the range ~1.97–2.37?MW/m2?K.