...
首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >Comparison of degenerative lumbar scoliosis correction and risk for mechanical failure using posterior 2-rod instrumentation versus 4-rod instrumentation and interbody fusion
【24h】

Comparison of degenerative lumbar scoliosis correction and risk for mechanical failure using posterior 2-rod instrumentation versus 4-rod instrumentation and interbody fusion

机译:Comparison of degenerative lumbar scoliosis correction and risk for mechanical failure using posterior 2-rod instrumentation versus 4-rod instrumentation and interbody fusion

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose Four-rod instrumentation and interbody fusion may reduce mechanical complications in degenerative scoliosis surgery compared to 2-rod instrumentation. The purpose was to compare clinical results, sagittal alignment and mechanical complications with both techniques. Methods Full spine radiographs were analysed in 97 patients instrumented to the pelvis: 58 2-rod constructs (2R) and 39 4-rod constructs (4R). Clinical scores (VAS, ODI, SRS-22, EQ-5D-3L) were assessed preoperatively, at 3 months, 1 year and last follow-up (average 4.2 years). Radiographic measurements were: thoracic kyphosis, lumbar lordosis, spinopelvic parameters, segmental lordosis distribution. The incidence of non-union and PJK were investigated. Results All clinical scores improved significantly in both groups between preoperative and last follow-up. In the 2R-group, lumbar lordosis increased to 52.8 degrees postoperatively and decreased to 47.0 degrees at follow-up (p = 0.008). In the 4R-group, lumbar lordosis increased from 46.4 to 52.5 degrees postoperatively and remained at 53.4 degrees at follow-up. There were 8 (13.8) PJK in the 2R-group versus 6 (15.4) in the 4R-group, with a mismatch between lumbar apex and theoretic lumbar shape according to pelvic incidence. Non-union requiring revision surgery occurred on average at 26.9 months in 28 patients (48.3) of the 2R-group. No rod fracture was diagnosed in the 4R-group. Conclusion Multi-level interbody fusion combined with 4-rod instrumentation decreased risk for non-union and revision surgery compared to select interbody fusion and 2-rod instrumentation. The role of additional rods on load sharing still needs to be determined when multiple cages are used. Despite revision surgery in the 2R group, final clinical outcomes were similar in both groups.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号