首页> 外文期刊>Computational intelligence and neuroscience >Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System
【24h】

Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System

机译:计算智能驱动的冷水相变能源热泵系统能耗特性实验试验

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In order to study the influence on the effective energy efficiency ratio, the energy consumption characteristics of a cold-water phase change heat pump system are discussed in this article. An experimental system of the cold-water phase-change energy heat pump system is designed and constructed, and then the deicing energy consumption and unit energy consumption of the heat pump system are analyzed by computational intelligence-powered methods. At last, the primary energy utilization ratio of the heat pump system is calculated. The results show that under the setting conditions, the deicing capacity of the heat pump system is about 0.135, the primary energy utilization ratio is about 1.145, and the COP (coefficient of performance) of the heat pump unit is between 2.8 and 3.2. Considering the system’s deicing energy consumption, the effective COP of the unit is between 2.42 and 2.76, so from this point, this kind of heat pump system can be widely used in the future. In order to improve the effective COP of the unit, the processes of ice making and melting should be further optimized to reduce heat loss and power loss.
机译:为了研究对有效能效比的影响,本文讨论了冷水相变热泵系统的能耗特性。设计并搭建了冷水相变能源热泵系统实验系统,然后利用计算智能方法对热泵系统的除冰能耗和单位能耗进行了分析。最后,计算了热泵系统的一次能源利用率。结果表明:在设定条件下,热泵系统的除冰能力约为0.135,一次能源利用率约为1.145,热泵机组的COP(性能系数)在2.8-3.2之间;考虑到系统的除冰能耗,机组的有效COP在2.42-2.76之间,因此从这一点来看,这种热泵系统在未来可以得到广泛的应用。为了提高机组的有效COP,应进一步优化制冰和融冰工艺,以减少热损失和功率损失。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信