For the outdoor insulation of high voltage transmission lines, insulating materials made of high-temperature vulcanized silicone rubber (HTV-SiR) are used all over the world. To enhance the performance of these base polymers, fillers of various sizes, concentrations and dimensions are added. In this study, four different types of HTV-SiR materials, one unfilled and three reinforced with silica of micro/nano size were used. Followed by preparation of the samples, aging was performed by placing them in a specially designed weathering chamber with various stresses and bipolar DC voltage for 5000 h. To diagnose integrity of the aged materials, different types of measurements based on hydrophobicity classification, leakage current, mechanical analysis, thermal tests, Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM) were conducted. Results of the hydrophobicity classification revealed S-3 to be most hydrophobic having HC2 class under the influence of bipolar DC voltage, whereas, sample S-1 was the most hydrophilic resulting in HC4 and HC5 under negative and positive DC voltages, respectively. Similarly, the lowest leakage currents of 5.56 mu A and 5.81 mu A were recorded for sample S-3 after being aged under negative DC and positive DC voltages, respectively. The age decrease in tensile strength recorded for samples S-1, S-2, S-3 and S-4 was 32.3, 25.32, 23.56 and 27.12, respectively, under the positive DC voltage. Thermogravimetric analysis exhibited the least decrease of yield from 49.3 to 48.9 and 48.4 for sample S-3 under negative and positive DC voltages, respectively. Additionally, according to FTIR spectroscopic investigation, hybrid composite S-3 kept the highest intactness in siloxane backbone (Si-O-Si) linkages, with a drop in its peak of 37 for positive DC and 11.2 for negative DC. In contrast to the co-filled composites S-2 and S-3 with improved surface morphology, samples S-1 and S-4 indicated voids, cracks, increased roughness and structural damages.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号