...
首页> 外文期刊>Medical Physics >Technical note: Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head‐and‐neck and brain tumors
【24h】

Technical note: Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head‐and‐neck and brain tumors

机译:Technical note: Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head‐and‐neck and brain tumors

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Purpose Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost and therefore more available to a larger patient population. Would the advances in pencil beam scanning (PBS) and robotics make gantry‐less treatment possible? In this study, we explore if the high‐quality treatment plans can be obtained without a gantry. Methods and materials We recently showed that proton treatments with the patient in an upright position may be feasible with a new soft robotic immobilization device and imaging which enables multiple possible patient orientations during a treatment. In this study, we evaluate if this new treatment geometry could enable high quality treatment plans without a gantry. We created PBS treatment plans for seven patients with head‐and‐neck or brain tumors. Each patient was planned with two scenarios: one with a gantry with the patient in supine position and the other with a gantry‐less fixed horizontal beam‐line with the patient sitting upright. For the treatment plans, dose‐volume‐histograms (DVHs), target homogeneity index (HI), mean dose, D2${D_2}$, and D98${D_{98}}$ are reported. A robustness analysis of one plan was performed with ±$ pm $2.5‐mm setup errors and ±$ pm $3.5 range uncertainties with nine scenarios. Results Most of the PBS‐gantry‐less plans had similar target HI and organs‐at‐risk mean dose as compared to PBS‐gantry plans and similar robustness with respect to range uncertainties and setup errors. Conclusions PBS provides sufficient power to deliver high quality treatment plans without requiring a gantry for head‐and‐neck or brain tumors. In combination with the development of the new positioning and immobilization methods required to support this treatment geometry, this work suggests the feasibility of further development of a compact proton therapy system with a fixed horizontal beam‐line to treat patients in sitting and reclined positions.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号