首页> 外文期刊>European journal of ophthalmology >Comparison of ultrasound energy consumption between low-energy femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery in patients with different cataract densities
【24h】

Comparison of ultrasound energy consumption between low-energy femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery in patients with different cataract densities

机译:Comparison of ultrasound energy consumption between low-energy femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery in patients with different cataract densities

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose Femtosecond laser-assisted cataract surgery (FLACS)'s effect on reducing ultrasound energy, accumulated with cumulative dispersed energy (CDE) units, still remains controversial. This study aims to evaluate the effect of low-energy FLACS on CDE with that of conventional phacoemulsification surgery (CPS) in different cataract densities from multiple surgeons. Methods It was a retrospective case-control study. Total 629 eyes receiving either low-energy FLACS (performed with Ziemer LDV Z8 platform) or CPS were divided into two groups according to preoperative grading of Lens Opacity Classification System III (LOCSIII): milder and harder cataract group. The mean CDE were compared in different cataract densities and surgeons. A linear regression analysis was performed to evaluate the effect of using low-energy FLACS on CDE in harder cataract cases. Results We found overall CDE had no significant difference between two surgeries. However, low-energy FLACS led to a significantly lower CDE in patients with harder cataracts than CPS (18.47 +/- 4.32 vs. 12.96 +/- 2.34; p < 0.001). Similar results were observed in the three surgeon subgroups and in linear regression analysis and no significant difference of the effect accounting for surgeons. Moreover, low-energy FLACS results in a reduction of energy consumption comparing to CPS and has endothelial sparring effect in patients with harder cataracts. Conclusions The reduced energy consumption was observed by using low-energy FLACS irrespective of surgeons' experience or the approaches adopted in patients with harder cataracts. Therefore, we can have more confidence to suggest this innovative platform to the patients in such cases.
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号