Performance of Intrusive Phase-Detection Probe with Large Sensor Size in Air-Water Flow Measurement and Application to Prototype Hydraulic Jump Study

机译:Performance of Intrusive Phase-Detection Probe with Large Sensor Size in Air-Water Flow Measurement and Application to Prototype Hydraulic Jump Study

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract A major challenge of prototype air-water flow measurement is the limited endurance of fragile phase-detection needle sensors in a high-momentum flow with risks of debris damage and particulate erosion. In the present study, a thick-tip conductivity probe is manufactured with sturdier needle sensors than the commonly used laboratory-sized probes. The large sensor tip had low chance to pierce small air bubbles and water droplets, leading to deterioration in the signal output quality, which prevents derivation of basic air-water flow properties using the conventional signal processing technique. To extract valid phase information from the low-quality signal, calibration experiments were conducted in laboratory with reference to a regular-sized probe, to explore a proper signal processing method for the thick-tip probe. The method was validated, and the thick-tip probe was deployed in a field hydraulic jump measurement, allowing for access to the air-water flow characteristics of the prototype D-type jump with a Reynolds number of 1.88×106. Despite the effort of signal calibration and compensation, the use of the thick-tip probe does not guarantee accurate bubble size measurement and requires higher sampling frequencies. Therefore, probes with fine sensor tips are still preferable in prototype measurement.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号