A new technique is assessed in order to measure, at the wafer scale, direct bonding energies. It is derived from the standard Double Cantilever Beam (DCB) method and uses interferometry in confocal IR laser source microscopy to measure crack openings. Such a bonding energy measurement protocol has better accuracy compared to other techniques. This is due to a better confocal microscopy resolution and the high intensity of the laser source. The elastic energy stored in bent wafers is obtained by measuring the beam curvature. DCB deformation models are discussed from the short-range crack opening theory to long distance beam-bending theories. Comparison is made between models, experimental results, and FEM simulations. Finally, the bonding energy error during standard measurements is estimated. Published under an exclusive license by AIP Publishing.
机译:评估了一种新技术,以便在晶圆尺度上测量直接键合能。它源自标准的双悬臂梁 (DCB) 方法,并在共聚焦红外激光源显微镜中使用干涉测量来测量裂纹开口。与其他技术相比,这种键合能量测量协议具有更高的准确性。这是由于更好的共聚焦显微镜分辨率和激光源的高强度。通过测量光束曲率获得弯曲晶圆中存储的弹性能。从短程裂纹开启理论到长距离波束弯曲理论,讨论了DCB变形模型。对模型、实验结果和有限元模拟进行了比较。最后,估计标准测量期间的键合能误差。在AIP Publishing的独家许可下出版。