首页> 外文期刊>Abdominal radiology. >Development of a volumetric pancreas segmentation CT dataset for AI applications through trained technologists: a study during the COVID 19 containment phase
【24h】

Development of a volumetric pancreas segmentation CT dataset for AI applications through trained technologists: a study during the COVID 19 containment phase

机译:Development of a volumetric pancreas segmentation CT dataset for AI applications through trained technologists: a study during the COVID 19 containment phase

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To evaluate the performance of trained technologists vis-a-vis radiologists for volumetric pancreas segmentation and to assess the impact of supplementary training on their performance. Methods In this IRB-approved study, 22 technologists were trained in pancreas segmentation on portal venous phase CT through radiologist-led interactive videoconferencing sessions based on an image-rich curriculum. Technologists segmented pancreas in 188 CTs using freehand tools on custom image-viewing software. Subsequent supplementary training included multimedia videos focused on common errors, which were followed by second batch of 159 segmentations. Two radiologists reviewed all cases and corrected inaccurate segmentations. Technologists' segmentations were compared against radiologists' segmentations using Dice-Sorenson coefficient (DSC), Jaccard coefficient (JC), and Bland-Altman analysis. Results Corrections were made in 71 (38) cases from first batch 26 (37) oversegmentations and 45 (63) undersegmentations and in 77 (48) cases from second batch 12 (16) oversegmentations and 65 (84) undersegmentations. DSC, JC, false positive (FP), and false negative (FN) mean (SD) in first versus second batches were 0.63 (0.15) versus 0.63 (0.16), 0.48 (0.15) versus 0.48 (0.15), 0.29 (0.21) versus 0.21 (0.10), and 0.36 (0.20) versus 0.43 (0.19), respectively. Differences were not significant (p > 0.05). However, range of mean pancreatic volume difference reduced in the second batch - 2.74 cc (min - 92.96 cc, max 87.47 cc) versus - 23.57 cc (min - 77.32, max 30.19). Conclusion Trained technologists could perform volumetric pancreas segmentation with reasonable accuracy despite its complexity. Supplementary training further reduced range of volume difference in segmentations. Investment into training technologists could augment and accelerate development of body imaging datasets for AI applications.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号