首页> 外文期刊>Clinical oncology >Validation of a Fully Automated Hybrid Deep Learning Cardiac Substructure Segmentation Tool for Contouring and Dose Evaluation in Lung Cancer Radiotherapy
【24h】

Validation of a Fully Automated Hybrid Deep Learning Cardiac Substructure Segmentation Tool for Contouring and Dose Evaluation in Lung Cancer Radiotherapy

机译:Validation of a Fully Automated Hybrid Deep Learning Cardiac Substructure Segmentation Tool for Contouring and Dose Evaluation in Lung Cancer Radiotherapy

获取原文
获取原文并翻译 | 示例
       

摘要

? 2023Background and purpose: Accurate and consistent delineation of cardiac substructures is challenging. The aim of this work was to validate a novel segmentation tool for automatic delineation of cardiac structures and subsequent dose evaluation, with potential application in clinical settings and large-scale radiation-related cardiotoxicity studies. Materials and methods: A recently developed hybrid method for automatic segmentation of 18 cardiac structures, combining deep learning, multi-atlas mapping and geometric segmentation of small challenging substructures, was independently validated on 30 lung cancer cases. These included anatomical and imaging variations, such as tumour abutting heart, lung collapse and metal artefacts. Automatic segmentations were compared with manual contours of the 18 structures using quantitative metrics, including Dice similarity coefficient (DSC), mean distance to agreement (MDA) and dose comparisons. Results: A comparison of manual and automatic contours across all cases showed a median DSC of 0.75–0.93 and a median MDA of 2.09–3.34 mm for whole heart and chambers. The median MDA for great vessels, coronary arteries, cardiac valves, sinoatrial and atrioventricular conduction nodes was 3.01–8.54 mm. For the 27 cases treated with curative intent (planned target volume dose ≥50 Gy), the median dose difference was –1.12 to 0.57 Gy (absolute difference of 1.13–3.25%) for the mean dose to heart and chambers; and –2.25 to 4.45 Gy (absolute difference of 0.94–6.79%) for the mean dose to substructures. Conclusion: The novel hybrid automatic segmentation tool reported high accuracy and consistency over a validation set with challenging anatomical and imaging variations. This has promising applications in substructure dose calculations of large-scale datasets and for future studies on long-term cardiac toxicity.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号