首页> 外文期刊>Optical fiber technology >All-fiber hydrofluoric acid sensor based on the dynamic corrosion process of the end face of a fiber tip
【24h】

All-fiber hydrofluoric acid sensor based on the dynamic corrosion process of the end face of a fiber tip

机译:基于光纤尖端端面动态腐蚀过程的全光纤氢氟酸传感器

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

An all-fiber hydrofluoric acid (HF) sensor based on the dynamic corrosion process of the end face (DCPEF) of a fiber tip is proposed in this study. HF detection can be easily realized by inserting the fiber tip protected by a ceramic ferrule into the HF solution. Theoretically and experimentally, the feasibility of the proposed DCPEF sensor for HF detection is demonstrated. The proposed sensor can detect HF concentration in a wide range of 0-40.00 wt, which is the widest detection range of HF concentration among contemporary HF detection methods. At HF concentration of 1.12 wt, the proposed sensor exhibits high sensitivity and a low corresponding measurement error of -1532 s/wt and 0.009 wt, respectively. Furthermore, the remote sensing capability of this sensor is proved. This remote sensing system shows similar sensing characteristics as the common sensing system. Compared with previous works, the proposed sensor has the advantages of easy fabrication, low cost, convenient operation, wide detection range, remote sensing capability, and so on; thus, it has great application prospects for HF detection.
机译:该文提出一种基于光纤尖端端面动态腐蚀过程的全光纤氢氟酸(HF)传感器。通过将由陶瓷套圈保护的光纤尖端插入 HF 溶液中,可以轻松实现 HF 检测。从理论和实验上验证了所提出的DCPEF传感器用于HF检测的可行性。该传感器可检测0-40.00 wt%的宽范围HF浓度,是当代HF检测方法中HF浓度检测范围最广的传感器。当HF浓度为1.12 wt%时,所提出的传感器表现出高灵敏度和低相应的测量误差,分别为-1532 s/wt%和0.009 wt%。此外,还证明了该传感器的遥感能力。该遥感系统具有与普通传感系统相似的传感特性。与以往工作相比,所提出的传感器具有制造方便、成本低、操作方便、检测范围广、具有遥感能力强等优点;因此,它在HF检测方面具有很大的应用前景。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号