Correlation Between Ultrasound-Measured Diameter and Blood Flow Velocity of the Internal Jugular Veins with the Preoperative Blood Volume in Elderly Patients

机译:Correlation Between Ultrasound-Measured Diameter and Blood Flow Velocity of the Internal Jugular Veins with the Preoperative Blood Volume in Elderly Patients

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The study aimed to explore the correlation of the diameter and blood flow velocity of the internal jugular vein with the preoperative blood volume in elderly patients and to providence for rapid evaluation of preoperative blood volume with ultrasound in elderly patients. Thirty patients over 65 years old were recruited in the study. Patient's central venous pressure (CVP) was recorded before anesthesia. The maximum diameter (Dmax) and the minimum diameter (Dmin) of the left internal jugular vein were measured by M type ultrasound and the respiratory variation index (RVI), defined as (Dmax - Dmin) / Dmax x 100%, was calculated. The maximum blood flow velocity (BVmax) and the minimum blood flow velocity (BVmin) were measured by Doppler ultrasound, and the blood flow variation index (BVI), defined as (BVmax - BVmin) / BVmax x 100%, was calculated. Then, each of the patients was given with 5 ml/kg crystalloid solution, and the relevant data were measured again and compared to that before infusion. The correlation between each measurement index and CVP, and their efficiency in predicting CVP > 6 mmHg were statistically evaluated. No matter before or after infusion, Dmax, Dmin, BVmax, and BVmin were positively correlated with CVP (Correlation is significant at the 0.01 level (2-tailed)); and RVI was negatively correlated with CVP (Correlation is significant at the 0.01 level (2-tailed)); however, BVI is negatively correlated with the CVP with no statistically significant difference. Through the analysis of ROC curve, Dmax, Dmin, RVI, BVmax, and BVmin could be used to predict the CVP > 6 mmHg in these patients, and the best index was BVmax; BVI diagnosis was not effective. Ultrasonic measurements of internal jugular vein diameter, respiratory variability, and blood flow velocity were correlated with preoperative CVP in elderly patients, indicating that these indexes could potentially be used to evaluate the preoperative blood volume in elderly patients.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号