...
首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws
【24h】

Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws

机译:马近端指间关节的微创关节融合术:以滞后方式插入的三个 5.5 毫米皮质螺钉和两个 7.0 毫米无头空心双节距压缩螺钉的生物力学比较

获取原文
获取原文并翻译 | 示例

摘要

Objective The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws AO-3TLS vs. two transarticular 7.0-mm headless cannulated multi-use compression screws MUC-2TS) in dynamic non-destructive testing and compression testing to failure. Study Design The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the remaining treatment. The dynamic test was performed alternating non-destructive compression tests at a displacement rate of 5 mm/min up to 5,000 N and sinusoidal compressive cyclic tests at 6 Hz, using a 3,600-N amplitude for 8,550 cycles. Construct stiffness and maximum sagittal plane rotation about the PIP joint markers were determined during the dynamic test. After the dynamic test reached 136,800 cycles, the monotonic compressive test until failure was performed on each construct: load, displacement and sagittal plane rotation about the PIP joint marker at failure were analysed. Results The evaluated biomechanical properties showed no statistical difference between the AO-3TLS and MUC-2TS treatment groups in any of the ramps of the dynamic non-destructive test and in the compression loading until failure test. Conclusion The MUC-2TS treatment produced biomechanical properties equivalent to the AO-3TLS treatment for PIP joint arthrodesis.
机译:目的 比较马近端指间关节(PIP)两种微创关节融合术(3个经关节5.5 mm皮质螺钉[AO-3TLS]与2个经关节7.0 mm无头空心多用途加压螺钉[MUC-2TS])在动态无损检测和加压试验中的生物力学特性。研究设计 实验研究包括六对尸体成年马前肢;每匹马的一个肢体被随机分配到其中一个治疗组,对侧肢体被提交到剩余的治疗组。动态测试以 5 mm/min 的位移速率进行交替无损压缩测试,最高可达 5,000 N,使用 6,600 N 振幅进行 8,550 次循环的正弦压缩循环测试。在动态试验中确定了结构刚度和围绕PIP关节标志的最大矢状面旋转。在动态测试达到 136,800 次循环后,对每个结构进行单调压缩测试,直到失效:分析失效时 PIP 接头标记的载荷、位移和矢状面旋转。结果 AO-3TLS和MUC-2TS处理组在动态无损检测的任一斜坡和压载荷直至失效试验中均无统计学差异。结论 MUC-2TS治疗PIP关节融合术的生物力学性能与AO-3TLS治疗相当。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号