Optimizing the Angiography Protocol to Reduce Radiation Dose in Uterine Artery Embolization: The Impact of Digital Subtraction Angiographies on Radiation Exposure

机译:Optimizing the Angiography Protocol to Reduce Radiation Dose in Uterine Artery Embolization: The Impact of Digital Subtraction Angiographies on Radiation Exposure

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose The aim was to compare a protocol of uterine artery embolization (UAE) consisting in three digital subtraction angiographies (DSAs)-Group A, with a protocol based on a single DSA-Group B. Materials and Methods This is a single-center prospective randomized study enrolling 20 women (mean age 41 years, range 22-55 years) with uterine fibroids treated with UAE, from January 2015 to February 2016. All UAEs were performed by two interventional radiologists using the same angiography machine. Protocol of Group A consisted in three DSA runs (non-selective pelvic view and selective uterine views before and after embolization). Protocol of Group B consisted in 1 DSA run: selective UA angiography before embolization. (Fluoroscopic roadmap was used for UA catheterization; fluoroscopy storage was used as control after embolization.) Each patient was randomized to receive Protocol A in one pelvic side and Protocol B on the other. Results All patients received bilateral UAE. Mean fluoroscopy time for UA catheterization was 11.3 +/- 3.7 s. (Protocol A) and 9.93 +/- 2.99 s. (Protocol B) (p = 0.19). Fluoroscopy dose for catheterization and embolization was not different between both protocols (p = 0.14). Identification of the UA origin score was similar in both protocols (median error = 0, p = 0.79). Mean dose area product (DAP) was 40859 mGy/cm(2) (Protocol A) and 28839 mGy/cm(2) (Protocol B) (p = 0.003). Mean effective dose (ED) decreased from Protocol A (14.6 mSv) to Protocol B (9.2 mSv; - 37%). Mean absorbed dose (AD) to ovaries and uterus, respectively, decreased of 53% and 55% from Protocol A to Protocol B. Conclusion Reducing the number of DSA runs from 3 to 1 during UAE allows at least a 30% reduction on radiation exposure, without compromising technical outcomes.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号