Simple, rapid, and reliable determination of the biuret content in urea fertilizer is very important for the development of fertilizer industry. A near infrared diffuse reflectance measurement system with a portable spectrometer was developed, in which the reference and dark background spectrum could also be recorded automatically in addition to the absorbance data. The key performances of the proposed NIR system have been tested on urea fertilizer. Numerical experiments showed that the coefficient of determination (R-2) of the external validation set was 0.97, with a root mean square error (RMSE) of 0.04. The ratios of the performance deviation (RPD) value in the calibration and validation sets were 12 and 3.5, respectively. It can be concluded that this NIR system for the determination of biuret content in urea fertilizer may potentially be used as an alternative method to traditional wet chemical methods due to its simplicity, sensitivity, and portability.
机译:尿素肥料中缩二脲含量测定简单、快速、可靠,对化肥工业的发展具有重要意义。开发了一种带有便携式光谱仪的近红外漫反射测量系统,该系统除了吸收率数据外,还可以自动记录参考光谱和暗背景光谱。所提出的近红外系统的关键性能已在尿素肥料上进行了测试。数值实验表明,外部验证集的决定系数(R-2)为0.97,均方根误差(RMSE)为0.04%。校准集和验证集的性能偏差(RPD)值之比分别为12和3.5。可以得出结论,这种用于测定尿素肥料中缩二脲含量的近红外系统由于其简单性、灵敏度和便携性,有可能用作传统湿化学方法的替代方法。