...
首页> 外文期刊>Archives of orthopaedic and trauma surgery. >A human, allogeneic cortical bone screw for distal interphalangeal joint (DIP) arthrodesis: a retrospective cohort study with at least 10 months follow-up
【24h】

A human, allogeneic cortical bone screw for distal interphalangeal joint (DIP) arthrodesis: a retrospective cohort study with at least 10 months follow-up

机译:A human, allogeneic cortical bone screw for distal interphalangeal joint (DIP) arthrodesis: a retrospective cohort study with at least 10 months follow-up

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction The prime requisites of a good digital arthrodesis are a painless and stable union in a proper position. Arthrodesis of the distal interphalangeal joint of the fingers is not without potential complications including nonunion, malunion, and deep tissue infections. The Shark Screw((R)) is a human, cortical bone allograft for osteosynthesis and an alternative to metal or bioabsorbable devices in orthopedics and trauma surgery. The primary hypothesis is that the fusion and complication rate, using the Shark Screw((R)), is at least similar to those reported in the literature, using metal or bioabsorbable screws. Material and methods This retrospective cohort study analyzes the fusion and complication rate and the patient satisfaction of distal interphalangeal joint arthrodesis of 27 fingers with the human allogeneic cortical bone screw. Complications, Disabilities of Arm, Shoulder, and Hand Questionnaire (Quick-DASH) score and Michigan Hand Outcomes Questionnaire (MHQ) score, grip and pinch strength and fusion angle were investigated. Results The mean follow-up was 23 months. At 6 weeks after surgery, fusion was obtained for all fingers. There was no surgical complication that required revision surgery. An average fusion angle of 13.6 degrees +/- 10.7 degrees was measured. VAS pain score decreased significantly from 6.9 before surgery to 0.14 after surgery. The Quick-DASH score decreased from 10.7 to 7.8. The MHQ score improved in all sub-scores. Conclusion The complication rates, using the Shark Screw((R)) for DIP joint arthrodesis, are lower compared to the results reported in the literature for other surgical techniques. Complications related to the human allograft cortical bone screw itself were not observed. The bone screw is completely remodeled into the host bone and further hardware removal is not necessary.
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号