首页> 外文期刊>IEEE Transactions on Nuclear Science >Boron-Coated Straws Imaging Panel Capability for Neutron Emission Computed Tomography for Source Localization Inside Radioactive Drums
【24h】

Boron-Coated Straws Imaging Panel Capability for Neutron Emission Computed Tomography for Source Localization Inside Radioactive Drums

机译:Boron-Coated Straws Imaging Panel Capability for Neutron Emission Computed Tomography for Source Localization Inside Radioactive Drums

获取原文
获取原文并翻译 | 示例
           

摘要

The evaluation of fissile mass inside radioactive waste drums by neutron measurements is essential for radioactive waste management, nuclear safety, and criticality issues. However, passive and active neutron measurements can be strongly impacted by the uncertainty on the neutron source position within the drum and by the matrix effects. Therefore, an imaging panel proposed by Proportional Technologies Inc., and composed of seven boron-coated straw (BCS) detectors has been tested to localize neutron interactions, in view to reduce uncertainties associated with plutonium or uranium position inside radioactive waste drums. In a previous work, a numerical model of the imaging panel has been developed and validated from a comparison with experimental profiles obtained with a 252Cf source. In the first section, the feasibility of neutron emission tomography by a setup composed of five extended imaging BCS panels is demonstrated by numerical Monte Carlo simulation. The second section details the experimental validation of the neutron emission tomography. Measurements are carried out with AmBe and 252Cf sources located inside an empty 118 L drum by rotating the BCS imaging panel around it. Afterward, the Richardson–Lucy deconvolution algorithm is applied to provide 2-D neutron source images for each angle. Finally, the 3-D images are reconstructed using the reconstruction toolkit (RTK) backprojection projection routine. The results demonstrate the capability of the BCS imaging to provide the 3-D location, i.e., axial and radial positions of one and two neutron sources. Furthermore, the first tests with this passive neutron measurement system show a satisfactory 3-D reconstruction for 252Cf and AmBe sources separated by 20 cm. Consequently, BCS imaging panels open interesting prospects to reduce the uncertainty associated with plutonium or uranium localization in neutron measurements. Work is undergoing to assess the capability of this system for 118 L drums filled with organic and metallic matrices. Additionally, further prospects concern the performance of other deconvolution and reconstruction algorithms.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号